Tektronix TLS 216 Hunting Equipment User Manual


 
Command Descriptions
2–62
TLS 216 Programmer Manual
CH1:BANDWIDTH?
might return FULL, which indicates there is no bandwidth limiting on
channel 1.
CH<x>:COUPling? (Query Only)
Returns the specified channel input coupling mode. The logic scope only
provides DC coupling; therefore this query always returns DC. This query is
only made available to maintain compatibility with Tektronix TDS model
instruments.
Vertical
CH<x>:COUPling?
COUPling
CH
<x>
?
:
DC
CH3:COUPLING?
always returns DC, indicating that channel 3 is set to DC coupling, the only
coupling mode available.
CH<x>:IMPedance? (Query Only)
Returns the specified channel input impedance setting. The logic scope only
provides 75 W input coupling; therefore this query always returns 75 W. This
query is only available to maintain compatibility with Tektronix TDS model
instruments.
Vertical
CH<x>:IMPedance?
IMPedanceCH <x> ?:
CH3:IMPEDANCE?
always returns 75, indicating channel 3 is set to 75 W impedance, the only
impedance available.
Examples
Group
Syntax
Returns
Examples
Group
Syntax
Examples