Tektronix TLS 216 Hunting Equipment User Manual


 
Command Descriptions
2–130
TLS 216 Programmer Manual
GROUP
<x>
:
HEIght
?
<Space> <NR3>
<NR3> is the height setting from 200E–3 to 8.0E+0.
GROUP2:HEIGHT 5
displays the HIGH and LOW levels for waveforms displayed in group 2 five
vertical divisions apart.
GROUP7:HEIGHT?
might return 2.0E+0 indicating the HIGH and LOW levels for waveforms
displayed in group 7 are spaced two vertical divisions apart.
GROUP<x>:LAST
Sets or queries the last channel in the group. Every group includes the first
channel (lowest numbered in the group), the last channel (highest numbered),
and every channel in between. A channel can only belong to one group at a time.
Vertical
GROUP<x>:FIRst, GROUP<x>:SELect
GROUP<x>:LAST <NR1>
GROUP<x>:LAST?
GROUP <x> :
LAST
?
<Space> <NR1>
<NR1> specifies the last channel in the group from 1 to 16.
GROUP2:LAST 5
sets the last channel in group 2 to channel 5.
GROUP8:LAST?
might return 16, indicating the last channel of group 8 is channel 16.
Arguments
Examples
Group
Related Commands
Syntax
Arguments
Examples