Command Descriptions
TLS 216 Programmer Manual
2–169
IMMed
:
:
MEASUrement
SOURCE
2
<Space>
?
CH
GROUP
REF
REF
<x>
<y>
<z>
<z> CH <x>
CH<x> specifies that channel <x> be waveform source for the immediate
measurement.
GROUP<y> specifies that the channel currently selected in group <y> be the
waveform source for the immediate measurement. The command GROUP<x>:SEĆ
LECT, described on page 2–133, sets the selected channel.
REF<z> specifies that the currently selected channel in reference group <z> be
the waveform source for the immediate measurement. The command
REF<x>:SELECT, described on page 2–212, sets the selected channel.
REF<z>CH<x> specifies that channel <x> in reference group <z> to be used as the
waveform source for the immediate measurement.
MEASUREMENT:IMMED:SOURCE2 REF3
sets the selected channel of reference group 3 as the waveform source for
making delay measurements.
MEASUREMENT:IMMED:SOURCE2?
might return REF1CH1, indicating the first channel of the first reference group
is the clock source.
MEASUrement:IMMed:TYPe
Specifies or returns the format of the Immediate measurement to be performed.
Measurement
MEASUrement:IMMed:TYPe { AMPlitude | AREA | BURst | CARea | CMEan
| CRMs | DELay | FALL | FREQuency | HIGH | HOLDTime | LOW |
MAXimum | MEAN | MINImum | NDUty | NOVershoot | NWIdth | PDUTy |
PERIod | PHAse | PK2pk | POVershoot | PWIdth | RISe | RMS |
SETUp | SKEw }
MEASUrement:IMMed:TYPe?
Arguments
Examples
Group