Tektronix TLS 216 Hunting Equipment User Manual


 
Command Descriptions
TLS 216 Programmer Manual
2–307
TRIGger
:
MAIn
SEQuence
:
:
STARt
<x>CH
:
LOW
X
<Space>
?
HIGH
HIGH specifies that the selected channel must be High relative to the threshold
level.
LOW specifies that the selected channel must be Low relative to the threshold
level.
X specifies that the selected channel can be either High or Low relative to the
threshold level.
TRIGGER:MAIN:SEQUENCE:START:CH14 HIGH
specifies that channel 14 must be High to meet the Boolean requirements of
the defined pattern for the main sequence trigger.
TRIGGER:MAIN:SEQUENCE:START:CH9 HIGH
might return LOW, indicating that channel 9 must be Low to meet the Boolean
requirements of the defined pattern for the main sequence trigger.
TRIGger:MAIn:SEQuence:STARt:INPut
Sets or queries the logic pattern input values for all 16 channels and the
Auxiliary Trigger input.
Trigger
TRIGger:MAIn:SEQuence:STARt:INPut <NR1>,<NR1>
TRIGger:MAIn:SEQuence:STARt:INPut?
TRIGger
:
MAIn
SEQuence
:
:
STARt
:
INPut
<NR1> , <NR1>
?
<Space>
Arguments
Examples
Group
Syntax