Tektronix TLS 216 Hunting Equipment User Manual


 
Command Descriptions
2–46
TLS 216 Programmer Manual
ACQuire:STOPAfter
Tells the logic scope when to stop taking acquisitions. Using this command is
equivalent to setting Stop After in the Acquire menu.
Acquisition
ACQuire:MODe, ACQuire:STATE
ACQuire:STOPAfter { RUNSTop | SEQuence }
ACQuire:STOPAfter?
STOPAfter
RUNSTop
ACQuire
:
?
<Space>
SEQuence
RUNSTop specifies that the run and stop state should be determined by the user’s
pressing the front-panel RUN/STOP button.
SEQuence specifies “single sequence” operation, where the logic scope stops
after it has acquired enough waveforms to satisfy the conditions of the acquisi-
tion mode. For example, if the acquisition mode is set to sample, and the
horizontal scale is set to a speed that allows real-time operation, then the logic
scope will stop after digitizing a waveform from a single trigger event. However,
if the acquisition mode is set to average 100 waveforms, then the logic scope
will stop only after all 100 waveforms have been acquired. The ACQuire:
STATE command and the front-panel RUN/STOP button will also stop
acquisition when the logic scope is in single sequence mode.
NOTE. If you set the acquisition system to single sequence, envelope mode, and
the number of envelopes to infinity, the logic scope will envelope a maximum of
2001 acquisitions.
ACQUIRE:STOPAFTER RUNSTop
sets the scope to stop acquisition when the user presses the front-panel
RUN/STOP button.
ACQUIRE:STOPAFTER?
might return SEQUENCE.
Group
Related Commands
Syntax
Arguments
Examples