Tektronix TLS 216 Hunting Equipment User Manual


 
Command Descriptions
2–182
TLS 216 Programmer Manual
REF<z>CH<x> specifies that channel <x> in reference group <z> is the waveform
source for the measurement.
NOTE. If a reference waveform is specified as a source, the waveform must have
a display type of ANALOGALL, ANALOGSEL, BUS, or TIMING.
MEASUREMENT:MEAS2:SOURCE1 CH1
specifies channel 1 as the measurement 2 source.
MEASUREMENT:MEAS2:SOURCE1?
might return REF1CH3, indicating channel 3 of reference #1 is the current
source waveform for this measurement.
MEASUrement:MEAS<x>:SOURCE2
Sets or queries the source to measure “to” when taking a delay or phase
measurement for MEAS<x>. MEAS<x> is one of the four measurements
available (named Measurement 1 through Measurement 4) where <x> specifies 1
through 4. Using this command is equivalent to setting the source in the Delay
from Selected Wfm side menu or the Phase from Selected Wfm side menu.
Measurement
MEASUrement:MEAS<x>:SOURCE2 { CH<x> | GROUP<y> | REF<z> |
REF<z>CH<x> }
MEASUrement:MEAS<x>:SOURCE2?
MEAS
:
:
MEASUrement
SOURCE
2
<Space>
?
CH
GROUP
REF
REF
<x>
<y>
<z>
<z> CH <x>
<x>
CH<x> specifies that channel <x> is waveform source for the measurement.
Examples
Group
Syntax
Arguments