Tektronix TLS 216 Hunting Equipment User Manual


 
Command Descriptions
TLS 216 Programmer Manual
2–285
TRIGger
:
MAIn
PATtern
:
:
QUAlifier
<Space>
?
RANge
LIMIT
LIMIT defines a maximum time limit for the main trigger event to occur.
RANge defines a range of time for the main trigger event to occur.
TRIGGER:MAIN:PATTERN:QUALIFIER RANGE
specifies that the main trigger event must occur either within or outside a
specified amount of time.
TRIGGER:MAIN:PATTERN:QUALIFIER?
might return LIMIT, indicating there is a maximum time limit for the main
trigger event.
TRIGger:MAIn:PATtern:RANge? (Query Only)
Returns the main pattern trigger range parameters.
Trigger
TRIGger:MAIn:PATtern:RANge?
TRIGger :
:
PATtern
MAIn ?
RANge
:
TRIGGER:MAIN:PATTERN:RANGE?
might return :TRIGGER:MAIN:PATTERN:RANGE:WHEN INSIDE;HIGHLIMIT
2.0E-9;LOWLIMIT 2.0E-9.
TRIGger:MAIn:PATtern:RANge:HIGHLimit
Sets or queries the value for the upper time limit of the range for the range-quali-
fied main trigger. Using this command is equivalent to selecting upper limit for
main pattern triggers with range selected as the time qualifier.
Arguments
Examples
Group
Syntax
Examples