Command Descriptions
TLS 216 Programmer Manual
2–253
TRIGger
:
DELay
SEQuence
:
?
END
:
TRIGGER:DELAY:SEQUENCE:END?
might return :TRIGGER:DELAY:SEQUENCE:END:LOGIC AND;INPUT
65537,2.
TRIGger:DELay:SEQuence:END:AUXiliary
Sets or queries the logic level expected at the rear panel connector labeled AUX
TRIGGER INPUT as part of the end pattern definition for delayed sequence
trigger.
Trigger
TRIGger:DELay:SEQuence:END:AUXiliary { HIGH | LOW|X}
TRIGger:DELay:SEQuence:END:AUXiliary?
TRIGger
:
DELay
SEQuence
:
:
END
AUXiliary
:
<Space>
?
LOW
HIGH
X
HIGH specifies that the Aux Trigger Input must be High relative to the threshold
level.
LOW specifies that the Aux Trigger Input must be Low relative to the threshold
level.
X specifies that the Aux Trigger Input can be either High or Low relative to the
threshold level.
TRIGGER:DELAY:SEQUENCE:END:AUXILIARY HIGH
specifies the Aux Trigger Input is High relative to the threshold level.
TRIGGER:DELAY:SEQUENCE:END:AUXILIARY?
might return X, indicating the Aux Trigger Input is either High or Low.
Examples
Group
Syntax
Arguments
Examples