Tektronix TLS 216 Hunting Equipment User Manual


 
Command Descriptions
TLS 216 Programmer Manual
2–87
If you wish to transfer complete waveforms only, set DATa:STARt to 1 and
DATa:STOP to the maximum record length.
DATA:STOP 1500
specifies that the waveform transfer will stop at data point 1500.
DATA:STOP?
might return 1490 as the last data point to be transferred.
DATa:TARget
Sets or queries the location for storing waveform data transferred to the
instrument using the CURVe command. This command is equivalent to the
DATa:DESTINATION command, and is included here for compatibility with
older Tektronix instruments.
Waveform
CURVe
DATa:TARget REF<z>CH<x>
DATa:TARget?
DATa
:
TARget
?
<Space> <z>
REF <x>CH
DATa:WIDth
Sets the number of bytes per data point in the waveform transferred using the
CURVe command.
Waveform
CURVe, WFMPre:BIT_Nr, WFMPre:BYT_Nr
DATa:WIDth <NR1>
DATa:WIDth?
Examples
Group
Related Commands
Syntax
Group
Related Commands
Syntax