MEASUrement:IMMed:SOURCE2
MEASUrement:IMMed:DELay:EDGE2 { FALL | RISe }
MEASUrement:IMMed:DELay:EDGE2?
IMMed
:
:
MEASUrement
DELay
:
EDGE2
<Space>
?
FALL
RISe
FALL specifies the falling edge.
RISe specifies the rising edge.
MEASUREMENT:IMMED:DELAY:EDGE2 RISE
specifies that the rising edge be used for the immediate delay measurement.
MEASUREMENT:IMMED:DELAY:EDGE2?
returns FALL showing that the falling or negative edge of the waveform is
used for the immediate delay measurement.