Measurement
MEASUrement:MEAS<x>:CLOCk:SOUrce { CH<x> | GROUP<y> | REF<z> |
REF<z>CH<x> }
MEASUrement:MEAS<x>:CLOCk:SOUrce?
MEAS
<x>
:
:
MEASUrement
CLOCk
:
SOUrce
<Space>
?
CH
GROUP
REF
REF
<x>
<y>
<z>
<z> CH <x>
CH<x> specifies that waveform <x> is the waveform selected as the clock source.
If CH<x> is specified, the channel must be included in a group.
GROUP<y> specifies that the channel currently selected in group <y> is the
waveform selected as the clock source. The command GROUP<x>:SELECT,
described on page 2–133, sets the selected channel.
REF<z> specifies that the currently selected channel in reference group <z> is the
waveform selected as the clock source. The command REF<x>:SELECT, described
on page 2–212, sets the selected channel.
REF<z>CH<x> specifies that channel <x> in reference group <z> is the waveform
selected as the clock source.
NOTE. If a reference waveform is specified as a source, the waveform must have
a display type of ANALOGALL, ANALOGSET, BUS, or TIMING.
MEASUREMENT:MEAS<x>:CLOCK:SOURCE REF<z>
specifies that the waveform in the currently selected channel in reference
group <z> is the clock source.
MEASUREMENT:MEAS<x>:CLOCK:SOURCE?
might return REF2CH2.