Tektronix TLS 216 Hunting Equipment User Manual


 
Command Descriptions
TLS 216 Programmer Manual
2–143
OFF or <NR1> = 0 sets the Response Header Enable State to false. This causes the
logic scope to omit headers on query responses, only the argument is returned.
HEADER OFF
causes the logic scope to omit headers from query responses.
HEADER?
might return the value 1, showing that the Response Header Enable State is
true.
HORizontal? (Query Only)
Returns all settings for the horizontal commands. The commands HORizon-
tal:MAIn:SCAle, HORizontal:MAIn:SECdiv, HORizontal:SCAle, and HORi-
zontal:SECdiv are equivalent. So HORizontal:MAIn:SCAle is the only value
returned.
Horizontal
HORizontal?
HORizontal
?
See “Example”
HORIZONTAL?
might return the string :HORIZONTAL:MODE MAIN;RECORDLENGTH 500;
POSITION 5.0E+0;TRIGGER:POSITION 50;:HORIZONTAL:MAIN:SCALE
1.0E-6;:HORIZONTAL:DELAY:MODE RUNSAFTER;SCALE 1.0E-6;TIME:
16.0E-9.
HORizontal:DELay? (Query Only)
Returns all horizontal delayed time base parameters. The commands HORizon-
tal:DELay:SECdiv and HORizontal:DELay:SCAle are identical, so HORizon-
tal:DELay:SCAle only is returned.
Horizontal
Examples
Group
Syntax
Returns
Examples
Group