Command Descriptions
2–44
TLS 216 Programmer Manual
ACQuire:NUMEnv
Sets or queries the number of waveform acquisitions comprising an envelope
waveform. Using this command is equivalent to setting the Envelope count in
the Acquisition Mode side menu.
Acquisition
ACQuire:MODe
ACQuire:NUMEnv { <NR1> | INFInite }
ACQuire:NUMEnv?
ACQuire
:
<NR1>
?
NUMEnv
<Space>
INFInite
<NR1> 0 is the number of waveform acquisitions, from 1 to 2000. The
envelope will restart after the specified number of envelopes have been acquired
or when the ACQuire:STATE RUN command is sent.
INFInite or <NR1> = 0 specifies continuous enveloping.
NOTE. If you set the acquisition system to single sequence, envelope mode, and
the number of envelopes to infinity, the logic scope will envelope a maximum of
2001 acquisitions.
ACQUIRE:NUMENV 10
specifies that an enveloped waveform will show the result of combining 10
separately acquired waveforms.
ACQUIRE:NUMENV?
might return 0, indicating that acquisitions are acquired infinitely for
enveloped waveforms.
Group
Related Commands
Syntax
Arguments
Examples