<NR1>
TRIGger
:
:
MAIn
HOLDOff
VALue
:
?
<Space>
<NR1> is from 0 to 100, and is a percentage of the holdoff range.
TRIGGER:MAIN:HOLDOFF:VALUE 10
sets the holdoff value to 10% of the holdoff range.
TRIGGER:MAIN:HOLDOFF:VALUE?
might return 0, indicating the main trigger holdoff value is 0%.
TRIGger:MAIn:LEVel
Set or queries the main trigger level. This command is equivalent to adjusting
the front panel TRIGGER THRESHOLD knob.
Trigger
TRIGger:MAIn:LEVel { TTL | ECLPlus | ECLMinus | CMOS | <NR3> }
TRIGger:MAIn:LEVel?
TRIGger :
:
MAIn
LEVel
<Space>
ECLMinus
?
CMOS
ECLPlus
TTL
<NR3>
TTL specifies a preset TTL level of 1.4 V.
ECLPlus specifies a preset level of 3.7 V.
ECLminus specifies a preset ECL level of –1.3 V.
CMOS specifies a preset level of 2.5 V.
<NR3> specify a new threshold in volts.