Tektronix TLS 216 Hunting Equipment User Manual


 
Command Descriptions
TLS 216 Programmer Manual
2–311
TRIGger:MAIn:STATE:CH<x>
Sets or queries the Boolean requirement (logic levels of High, Low, or Don’t
Care) for the selected channel. The Boolean requirements set for all the trigger
inputs define the logic pattern that triggers the logic scope.
Trigger
TRIGger:MAIn:STATE:CH<x> { HIGH | LOW | X } NOTE: defines CH<x>
pattern bit to High, Low or Don’t Care
TRIGger:MAIn:STATE:CH<x>?
TRIGger
:
MAIn
STATE
:
:
CH
<x>
LOW
X
<Space>
?
HIGH
HIGH specifies that the selected channel must be High relative to the threshold
level.
LOW specifies that the selected channel must be Low relative to the threshold
level.
X specifies that the selected channel can be either High or Low relative to the
threshold level.
TRIGGER:MAIN:STATE:CH14 HIGH
specifies that channel 14 must be High to meet the Boolean requirements of
the defined pattern for the main state trigger.
TRIGGER:MAIN:STATE:CH11?
might return LOW, indicating that channel 11 must be Low to meet the
Boolean requirements of the defined pattern for the main state trigger.
Group
Syntax
Arguments
Examples