Track Operations 187
(Continued from previous page)
LCD Display Action
Notes: If Event/Heat is selected, the Event/Heat
value will be updated automatically when an
external timer code is used.
Use the SCORE setting if you do not want the
values to be updated externally in an external timer
code.
Switch Output
The All Sport 5000 series console has a switch that can be used to drive a number of different
devices. The switch can be configured to operate under different settings. The default
setting is 1-CLOCK= 0.
To display the switch setting that you want to select:
• Press the number (0,1,2,3) key as a shortcut or use the left and right arrow keys to
scroll to the desired setting.
• Press <YES> to select the new setting.
• Press <NO> or the down arrow key to leave the switch setting and display the next
prompt.
The possible settings for the switch output are as follows:
Setting Result
0-DISABLED
SWITCH OUTPUT=n
0-DISABLED?
n = current setting
The switch remains open at all times and any external
devices are disabled.
1-CLOCK = 0
SWITCH OUTPUT=n
1-CLOCK =0?
n = current setting
In count down mode, the switch closes when the
main clock reaches zero and remains closed until a
nonzero value is entered.
In count up mode, the switch closes when the main
clock reaches the proper period, break, or overtime
length and opens when any other value is entered.
(Continued on next page)