Football Options 129
The possible settings for the switch output are as follows:
Setting Result
0-DISABLED
SWITCH OUTPUT=n
0-DISABLED?
n = current setting
The switch remains open at all times and any
external devices are disabled.
1-CLOCK = 0
SWITCH OUTPUT=n
1-CLOCK =0?
n = current setting
In count down mode, the switch closes when the
main clock reaches zero and remains closed until a
nonzero value is entered.
In count up mode, the switch closes when the main
clock reaches the proper period, break, or overtime
length and opens when any other value is entered.
2-CLOCK STOP
SWITCH OUTPUT=n
2-CLOCK STOP?
n = current setting
The switch closes when the main clock is stopped
and opens when the main clock is running. External
devices are disabled when the main clock is running.
3-MAIN HORN
SWITCH OUTPUT=n
3-MAIN HORN?
n = current setting
The switch closes when the main horn sounds. This
could be when Auto Horn is enabled and the main
clock reaches zero or when <HORN> is pressed.