6 - 5
– +
ELEC
IGNITION SYSTEM
MAIN SWITCH INSPECTION
1. Inspect:
● Main switch conduct
Continuous while the main switch is moved to
“OFF” → Replace.
Not continuous while the main switch is moved
to “ON” → Replace.
2. Inspect:
● Main switch indicator light
Use 12 V battery.
Indicator light does not come on → Replace.
3. Inspect:
● Rubber part a
Tears/damage → Replace.
Tester (+) lead → Red lead 1
Tester (–) lead → Brown lead 2
R
1
Br
2
Tester selector
position
ON
Ω × 1
OFF
Battery (+) lead → Red/Black lead 1
Battery (–) lead → Black lead 2
a
EC626002
IGNITION COIL INSPECTION
1. Remove the ignition coil cap.
2. Inspect:
● Primary coil resistance
Out of specification → Replace.
Tester (+) lead → Orange lead 1
Tester (–) lead → Black lead 2
Primary coil
resistance
Tester selector
position
0.08 ~ 0.10 Ω at
20 ˚C (68 ˚F)
Ω × 1