Parker Hannifin VIX250IM Stepper Machine User Manual


 
3. ELECTRICAL INSTALLATION 35
X5 Connector
X5 is the user Input/Output connector.
Connector Type
Connector type is a high-density 15-way D-type plug.
Connector Pin Out
Connector Pin X5 Input/Output
10V
20V
30V
4 Output 2
5 Output 1
6 Input 5 (limit+)
7 Input 4 (limit-)
8 Input 3 (home)
9 Input 2 (registration)
10 Input 1 (stop)
11 +24V
12 +24V
13 +24V
14 Output 3
15 Reserved
Table 3-11. X5 User Input/Output Connections