Parker Hannifin VIX250IM Stepper Machine User Manual


 
30 VIX IM MICROSTEPPER INDEXER DRIVE USER GUIDE
Motor Overtemperature Sensor
Standard Parker stepper motors do not use an over-temperature sensor, however when
using custom motors provision is made for the connection of either a thermal switch or
thermistor device. The following devices are supported:
Thermik SNM130ES
Cantherm F11 110-2-5 U106
Other ptc thermistors with a switch like characteristic are supported to DIN44081/44082.
The input requires a normally closed switch to be connected to GND on X2 pin 3 or 6.
If you use a custom motor with no overtemperature sensor fitted, make sure you leave the
Thermal sensor fitted check box un-checked in the Custom Motor Set Up screen, within
Easi-V to prevent an overtemperature fault being reported. This is the default setting in
Easi-V.
X3 Connector
X3 is the RS232/RS485 communications connector. RJ45 connectors X6 and X7 may also
be used for inter-drive communications where multi-axis systems are used.
RS485 Operation
RS485 operation is only possible on drives fitted with the appropriate FEM (Fieldbus
Expansion Module). If you require this feature please order the ViX CM drive type.
Connector Type
Connector type is a 9-way D-type socket.
Connector Pin Out
Connector Pin X3 Function
1 Rx+/Tx+ (RS485)
2
drive reset
3 RS232 GND
4 RS232 Rx
5 RS232 Tx
6 Rx-/Tx- (RS485)
7 RS232 Tx (D loop)
8 Do not connect
9 +5V output
Table 3-8. X3 RS232/RS485 Connections