Parker Hannifin VIX250IM Stepper Machine User Manual


 
28 VIX IM MICROSTEPPER INDEXER DRIVE USER GUIDE
Terminal Description
X1 Connector
X1 is the main power and motor connector. Both HV, +24V and the motor phase
connections are made to X1.
Connector Type
The mating connector for X1 is a Wieland 8213B/10F, part number 25.323.4053.0 (Parker
part number 0405.811). An approval marked version of this connector has the part number
25.323.1053.0.
Connector Pin Out
Connector Pin X1 Signal Name
10 24 to 80V DC +HV
9 0V/GND -HV
8 Earth PE
7 24V DC
6 0V (GND for 24V DC)
5 Motor Earth
4 Motor phase (A+)
3 Motor phase (A-)
2 Motor phase (B+)
1 Motor phase (B-)
Table 3-6. X1 Power and Motor Connections
Motor Connections at the Drive
Refer to the EMC installation information earlier in this section.