Parker Hannifin VIX250IM Stepper Machine User Manual


 
3. ELECTRICAL INSTALLATION 11
WARNING
The drive HV supply input is not reverse polarity protected.
Reverse polarity connections will damage the drive.
Current and Capacitance
A supply must have a minimum amount of capacitance to support a drive at peak power
draw.
Drive Type DC Supply Current Supply Capacitance
ViX500 5.6A RMS
6600µF
ViX250 2.8A RMS
3300µF
Table 3-2. Drive Supply Currents
+24V Requirements
Both drive types require a +24V controller and logic supply. The supply may also be
required for an encoder and a Fieldbus Expansion Module (FEM).
Absolute voltage range 20 to 27V
Nominal drive current 250mA (excluding encoder, & FEM)
Encoder supply loading 150mA (if required)
FEM current 50mA
Safety Earth Requirements
Earth the drive using the earth pin on X1 (pin 8).
Power Supply Options
A set of torque curves (Figure 3-2) for various motor/drive combinations can be used for
calculating an applications likely power requirements.
Higher torque/current requirements will need to use the ViX500 drive and a high current
linear supply, such as the PL1100. Further power supply information is given in Appendix A.