Utility Commands
557
ProSafe Managed Switch
no logging email urgent
This command resets the urgent severity level to the default value.
Format no logging email urgent
Mode
logging email message-type to-addr
This command configures the email address to which messages are sent. The message
types supported are urgent, non-urgent, and both. For each supported severity level,
multiple email addresses can be configured. The to-email-addr variable is a standard email
address, for example admin@yourcompany.com.
Format logging email message-type {urgent |non-urgent |both}
to-addr <to-email-addr>
Mode
no logging email message-type to-addr
This command removes the configured to-addr field of email.
Format no logging email message-type {urgent |non-urgent |both}
to-addr <to-email-addr>
Mode
logging email from-addr
This command configures the email address of the sender (the switch).
Default
Format logging email from-addr <from-email-addr>
Mode
no logging email from-addr
This command removes the configured email source address.
Format no logging email from-addr <from-email-addr>
Mode
Global Config
Global Config
Global Config
switch@netgear.com
Global Config
Global Config