Tektronix TAS 455 Hunting Equipment User Manual


 
Removal and Installation Procedures
Maintenance
6Ć28
Additional procedures required Ċ This procedure requires that the
following procedures be performed first:
H Rear Cover Removal
H Cabinet Removal
H Front Trim Removal
1. From the front of the Implosion Shield, slip the spudger into the slot
provided on the side of the CRT Front Bracket. See Figure 6Ć15.
2. Carefully pry the Implosion Shield up and out of the CRT Front Bracket
guides.
3. ReĆinstall the Implosion Shield by placing the left side of the shield into
the CRT Front Bracket guides. If installing a new Implosion Shield,
remove the clear protective covers.
4. Snap the right side of the Implosion shield into the CRT Front Bracket
snaps.
5. Install all previously removed components.
CRT Implosion
Shield
Spudger
Slot In CRT Bracket
Implosion Shield
Guides