158 VIX IM MICROSTEPPER INDEXER DRIVE USER GUIDE
Profile
number
12
Acceleration 200 150
Deceleration 200 200
Distance 1500 4800
Velocity 25 45
The move parameters specified by Profile 2 may be
used (that is, copied to profile 0) with the statement ........
4USE(2)
Note
A profile command will overwrite any individually programmed values of
acceleration, deceleration, distance and velocity once the USE command is
issued.