Parker Hannifin VIX500IM Stepper Machine User Manual


 
126 VIX IM MICROSTEPPER INDEXER DRIVE USER GUIDE
E
Enable/Disable Communications
Syntax Units Range of n Default See also
aEn - 0 or 1 1 -
Description The E command disables or re-enables serial communications.
E1 turns command communications ON, whilst E0 turns it OFF. In E0 mode
the only command seen by the controller is E1.
Properties
Immediate or buffered, cant be used in labelled block, E1 saved by SV
Example
An example of when to use this command is if global
commands are being sent but one axis needs to ignore
them whilst all others action them.
To enable axis 6 to accept commands over the RS232
serial link, type .................................................................
6E1
To disables communications using the RS232 serial
link, type ...........................................................................
6E0