Parker Hannifin VIX500IM Stepper Machine User Manual


 
6. COMMAND REFERENCE 131
G
Go
Syntax Units Range of n Default See also
aG - - - PS S K M
Description Issuing a G command starts motion using the parameters specified by the V,
A or AA/AD, and D commands or via the PROFILE and USE commands.
The mode of motion must have been previously set as this determines which
parameters are used and which are ignored. For example, mode continuous
will ignore the distance parameter.
Properties
Immediate or buffered, can be used in labelled block, not saved by SV
Example 1PROFILE3(150,200,1500,25) ;define profile 3
1USE(3) ;use profile 3
1G ;perform profile 3
Note
If no motion occurs after G is issued, the cause can be determined by using
the R(UF) command. Refer to the section on system parameters for more
information.