Star Trac TR 4500 Treadmill User Manual


 
Maintenance Mode
Parameters Lowest
Value
Highest
Value
Option 1 Option 2 Default
Value
Meaning
KEY DN
0 255 --- --- 0 Number of times the
Stop Switch was down
or disconnected on
power-up since last
reset.
NO RPM
0 255 --- --- 0 Number of times the
display did not detect
a RMP signal.
SP CNG
0 255 --- --- 0 Number of times a
sudden change in
speed was detected
EL STL
0 255 --- --- 0 Number of times an
elevation stall was
detected.
EL RNG
0 255 --- --- 0 Number of counts per
RPM Sensor
revolution.
EL LOST
0 255 --- --- 0 Number of times no
elevation was
detected.
ELZERO
0 255 --- --- 240 Represents the incline
number for 0%.
EL MAX
0 255 --- --- 57 Represents the incline
number for 15%.
LSTERR
0 25 --- --- 0 Indicates what display
code appeared last.
18 = NO STO
19 = KEYDN
20 = NO RPM
21 = SP CNG
22 = EL STL
23 = EL RNG
24 = EL LOST
LSTELV
0 255 --- --- 0 Displays the target
elevation prior to the
display code.
LSTPOT
0 255 --- --- 0 Displays the incline
number prior to the
display code.
3.6