Star Trac TR 4500 Treadmill User Manual


 
Maintenance Mode
Parameters Lowest
Value
Highest
Value
Option 1 Option 2 Default
Value
Meaning
HRT CON
--- --- ON OFF OFF OFF= Heart Control
disable
ON= Heart Control
enabled
HRT
--- --- CNT DN
POLAR
CONTACT
BOTH
CNT DN
POLAR
CONTACT
BOTH
CNT DN CNT DN= Manual
countdown heart rate
POLAR, CONTACT or
BOTH (Polar &
Contact)
10 REV
22.0 74.0 30.7 = For
110v units.
35.8 = For
220v units
29.1 Inches of running belt
travel for 10 flywheel
revolutions, measured
in inches.
1.8” pulley:30.7 (110v)
2.1”pulley:35.8(220v)
CNT/REV
1 255 31 =
Magnetic
RPM Sensor
125 =
Optical
Sensor
31 Number of counts per
RPM Sensor
revolution.
MN PWM
2 50 --- --- 30 Minimum PWM to
obtain minimum
speed, automatically
done.
1/2 PWM
25 170 --- --- 130 1/2 Maximum PWM to
obtain 1/2 maximum
speed, automatically
done.
MX PWM
86 255 --- --- 230 Maximum PWM to
obtain maximum
speed, automatically
done.
DATE
1.00 12.99 --- --- 1.96 Treadmill
manufacturing date.
NO STO
0 255 --- --- 0 Number of times the
Stop Switch was down
or disconnected on
power-up since last
reset.
3.5