Owner’s Manual: Advanced Programming and Troubleshooting 57
Troubleshooting Error Codes
If any error codes appear in the center display, turn the unit
Off and On. If the error continues to occur, call an authorized
service person for assistance. Refer to Obtaining Service.
Troubleshooting Heart Rate
Table 5 may help you understand and troubleshoot erratic
heart rate readings.
Important: A heart rate can only be detected when the
Precor heart rate receiver is properly installed in the display
and the treadmill is turned On. You must also wear the chest
strap or hold on to both touch-sensitive grips.
To conduct electrical impulses from a user’s heart, both
touch-sensitive grips must be grasped firmly for five to ten
seconds. Usually, the concentration of salts in a person’s
perspiration provides enough conductivity to transmit a
signal to the receiver in the display console. However,
because of body chemistry or erratic heartbeats, some
people cannot use the heart rate feature. A chest strap may
provide better results. Refer to the QuickStart Card for
proper placement of the chest strap.
Table 5. Erratic heart rate readings
What appears
on the display Cause What to Do
Nothing The heart rate
receiver is not
installed or it has
been disconnected.
To receive Customer
Support, refer to
Obtaining Service.
— — — A signal is being
detected, but the
transmission requires
more time to
establish a heart rate.
Be sure the chest strap
is in direct contact with
your skin.
Hr A signal is being
detected, but the
transmission requires
more time to
establish a heart rate.
Appears on the 9.33
only.
If using the touch-
sensitive grips, use
both hands and make
sure your hands are
moist, not dry.
Pulsing HEART The LED heart blinks
when a heart beat is
detected.
If the LED is pulsating,
it indicates that the
heart rate equipment is
working properly.
M9.33-931_Owners Manual.book Page 57 Friday, January 11, 2008 7:42 AM