Cybex International 710T Treadmill User Manual


 
Cybex 710T Treadmill Owner’s Manual
Page 7-18
C14: PGM LOCKOUT
This mode allows the programs to be turned off, for manual use only.
Press the + key to turn the lockout feature on, disabling all programs. Press the key to turn
the lockout feature off, enabling all programs. Press START/ENTER to set your selection.
C15: TIME LIMIT
Use the SCAN/SAVE key to toggle the time limit feature off and on, as shown on the display.
When the time limit number of minutes (5 to 95 in 5-minute increments) is displayed, it may
be incremented with + or
^
key or decremented with or v key.
The control panel displays the test results until you press START/ENTER.
NOTE: When a time limit is set, the display scrolls “MAX WORKOUT XX Min”, when a workout
is selected.
C16: SPEED LIMIT
Use the + or key to increment the speed limit from 1.1 to 10.0 mph (1.8 to
16 kph). At 10 mph (16 kph) it has no effect. At lower values it limits the speed in both the
manual and program modes. Use START/ENTER to confirm
and save.
C17: PAUSE TIME
Using the + and keys, set the pause time to 0:10 Min or 5:00 Min, as shown on the display.
Your selection determines the time that a workout may be delayed after the STOP key is
pressed. If the workout is not re-accessed during this time period the workout terminates
automatically.
C18: POWER RELAY TEST
This test allows you to test (activate) the power relay on the lower electronics PCB. Pressing the v
elevation button in conjunction with the SPEED + button will toggle the relay on/off. You should
be able to hear the relay toggle and note as well that the value in the right window should read
“1.” If the number displayed in the right control panel window is “1,” then the power relay control
wiring is OK. If the value displayed is “0,” then the relay can not be controlled by the display.
C19: SERVICE REMINDERS
Service reminders occur every 5000 miles to bring your attention to the regular scheduled
maintenance which should be performed for maximum treadmill life and performance. Once in
this screen, you have the option to clear a service reminder and to turn this feature on or off.
Use the - / + keys to toggle the displayed message. If a Service Reminder is active, this
allows you to clear it. If no Service Reminders are active, you have the option of toggling the
feature on and off. Press START/ENTER to accept any changes and exit the screen.
Press STOP to exit and return to the mode you were in before entering the diagnostic tests.