Fluke PM3370B Hunting Equipment User Manual


 
FUNCTION REFERENCE 5 - 21
CURSORS BOTH
In this mode, both voltage and
time cursors are active. The
TRACK and controls operate as
in VOLT or TIME mode, as
selected with the CONTROL key.
Key sequence:
Control to shift both cursors simultaneously, or to shift the
track cursor only. Selection in the CURSORS READOUT
menu determines one of the two.
Control to shift the cursor.
Remote commands:
CPL: QM (command to query measured values)
Refer to Chapter 6 for full details.
CURSORS
on
ch1
ch2
ST6554
9303
CONTROL
READOUT
ch2T=... V=...
TRACK
TRACK
off
-
-
Toggle function softkey to switch between cursors on and off.
Toggle function softkey to switch between volt, time or both
cursors.
Softkey pair to select CH1 or CH2 for measurements. Selects in
digital mode also stored traces.
Toggle function softkey to switch between volt and time cursors
for positioning. This selection is usable only in the ’both’ cursor
mode.
TRACK