Brother BAS-761 Watch User Manual


 
39
BAS-761
Error code
E – 800
E – 801
E – 802
E – 803
E – 810
E – 820
E – 821
E – 830
E – 840
E – 850
E – 860
E – 870
E – 880
E – 890
E – 900
E – 901
E – 902
E – 903
E – 910
E – 920
E – 960
E – 970
Reset
Yes
Yes
No
Yes
No
Yes
No
No
No
No
No
No
No
No
No
No
No
No
No
No
No
No
Contents
EMERGENCY STOP button pressed
EMERGENCY STOP button pressed during sewing
EMERGENCY STOP button pressed during programming
EMERGENCY STOP button pressed during programming
EMERGENCY STOP button is not connected
No air, or air chuck is turned off
No air, or air chuck is turned off
X right overtravel switch activated
X left overtravel switch activated
Y up overtravel switch activated
Y down overtravel switch activated
X motor problem
Y motor problem
Machine head motor problem
Outer work clamp cylinder malfunction or sensor malfunction
Inner work clamp cylinder malfunction or sensor malfunction
Gauge forward/back cylinder malfunction or sensor malfunction
Base 10 cylinder malfunction or sensor malfunction
X axis positioning error
Y axis positioning error
Clamp-in sensor malfunction
Clamp malfunction
12. Table of error code
* If the primary-side voltage is lower than the rated level at low temperatures, the error message “E-890” may appear
at the sewing start. If this happens, set DIP switch A-7 to ON.