Groundsmaster 4000--D Page 5 -- 7 Electrical System
Cutting Deck Operating Problems
The cutting decks remain engaged, but should not,
with no operator in the seat.
The seat switch or circuit wiring is faulty.
Cutting decks run, but should not, when raised. Decks
shut off with PTO switch.
The deck position switch or circuit wiring is faulty.
Cutting decks run, but should not, when raised. Decks
do not shut off with the PTO switch.
The deck position switch or circuit wiring and PTO
switch or circuit w iring are faulty.
A hydraulic problem exists (see Troubleshooting
section of Chapter 4 -- Hydraulic System).
Cutting decks run, but should not, when lowered with
PTO switch in the OFF (disengage) position.
The PTO switch or circuit wiring is faulty.
Cutting deck(s) do not operate. The operator is lifting off the seat switch.
Traction circuit is in transport mode.
The seat switch or circuit wiring is faulty.
The PTO switch or circuit wiring is faulty.
The deck position switch or circuit wiring is faulty.
The transport/4WD switch or circuit wiring is faulty.
Hydraulic valve solenoid(s) or circuit wiring is faulty.
A hydraulic problem exists (see Troubleshooting
section of Chapter 4 -- Hydraulic System).
Cutting decks shut off when PTO switch is released
from the engage position.
Diode circuit board or circuit wiring is faulty.
PTO fuse fails when engaging cutting deck. Hydraulic valve solenoid coil is shorted.
Cutting deck position switch is faulty.
Electrical