Soehnle 3030 Fitness Equipment User Manual


 
English
88
2. Basic functions
The basic functions are similar or identical for all application programs.
2.1 Power on/off
Power-on
After power-on and during the run-up phase, the
Soehnle Professional
logo is
displayed.
The measuring points are briefly listed as they are detected.
The scale is zeroed after the power-on routine
(this may differ with non calibratable calibration).
After power-on, the last application program activated is reopened.
Zero range limits at power-on
Calibratable: Zero range at power-on 20% of the weighing range.
The default value is -5% to +15% of the weighing range.
Non calibratable: Zero range at power-on -99% to +99% of the weighing range.
If power-on is outside the zero range at power-on, the scale displays error message
Error 50 / 51 Value outside zero range limit.
When the cause for overload or underload is rectified, the scale is zeroed without
having to switch the appliance on and off and is ready to operate.
Response to power failure
The scale returns to the previous settings when power is restored.
Power-off
Press the On/Off key.
If the activated measuring point is loaded or a menu is open, the scale switches off
only 3 seconds after the On/Off key is pressed.
2.2 Selecting a program
Select one of the application programs from the list.
Press the function change key (F>) to switch to the Setting Functions level.
Press F5 Program.
You can now choose from 10 different application programs.
Selecting a program: Press arrow key F3 Up or F4 Down. Accept by pressing F6.
Gross X 10 Unit Program
Setting
mode