Soehnle 3030 Fitness Equipment User Manual


 
English
2277
Switch between part and percent by pressing the function change key F>. If you wish to define
the plus and minus tolerances separately, activate the "+/- tolerance separate" function in Setting mode.
The display switches to the Count display view. The special characters are activated.
The relevant special character is displayed next to the setpoint depending on the actual weight on the
scale.
Quantity check special character
You can also display the difference between actual values and setpoint weights at the top left of the
additional display in figures with a + or - sign. Activate the additional display by pressing F3 Unit in Level
4 Setting Functions.
If you activated a memory location containing setpoints and tolerances in the Ref Fixed memory, the
special characters are activated automatically.
A totalising/batching operation (accept in the total memory by pressing the Plus key) interrupts the
display of the quantity check special character until the scale is clipped off. The quantity check special
character is then reactivated.
Displaying the setpoint and tolerance
Press the Info key and then F3 "Quant. Check" or press the "Quant. Check" key in Level 2 Checking
Functions. The current values then appear in the display box.
Switching points for quantity check
See the description of the function in the CD manual.
Data record/Printout within or outside the tolerance
You can inhibit or accept release of a data record if it is outside a specific tolerance band. If a data
record is released outside a tolerance, it is marked by a special
character.
The function is released or inhibited in Setting mode (see manual).
Startmode
When Start mode is activated, the scale freezes the switching point after the switching point is reached.
The scale can then be clipped off without deactivating the switching point, thus preventing the start of an
undesired new operation. Only after you press F6 Start is the freeze state cancelled.
Activate Start mode in Setting mode (see manual).
under tolerance point
within tolerance
Setpoint exactly reached
over tolerance point
Ba_3030_GB_neu.qxd 04.12.2006 11:02 Seite 27