Soehnle 3030 Fitness Equipment User Manual


 
English
3300
3.4.2 Check display view
Tip: An additional way to display the deviation from the setpoint on the calibrated unit is to activate the
additional display by pressing F3 Unit in the Setting Functions level.
3.4.3 Taring
Taring functions same as for 3.1 Weighing and taring.
3.4.4 Checking functions
Type in setpoints.
Press F1 Setpoint in Level 1 Checking Functions. You can now place a sample part on the scale to
accept the setpoint or type in the setpoint into the calibrated unit using the numerical keypad .
Confirm by pressing F6 Accept. Type the required tolerance in parts or percent into the numerical
keypad and confirm by pressing F6 Accept. Switch between part and percent by pressing the F> key.
If you wish to define the plus and minus tolerances separately, activate the "+/- tolerance separate"
function in Setting mode (see CD manual). The display switches to the Check display view. The special
characters are activated. The associated special character is displayed next to the setpoint depending
on the actual weight on the scale.
Check special characters
under tolerance point
within tolerance
Setpoint exactly reached
over tolerance point
Ba_3030_GB_neu.qxd 04.12.2006 11:02 Seite 30