Precor P10 Heart Rate Monitor User Manual


 
Setting Up the Console 27
Event
Number
Description of Event
31 Incorrect Communications event upper board to lower
board
32 Communication event upper board to lower board
33 Incorrect communications event lower board to upper
board
37 E-STOP error (treadmill only)
40 Lift motion detected
42 Lift position value out of range
43 Zero switch not found
44 Un-commanded lift motion
45 Lift going in the wrong direction
50 Too much brake (magnet) current
53 Cannot read target, cannot find home switch
54 Target pulses lost during operation
55 Brake home switch activated unexpectedly
60 Auto Stop sensor failure (treadmill only)
61 Auto Stop not present (treadmill only)
62 Vertical sensor failure (AMT only)
70 Belt replacement, lower control board not read (AMT
only)
71 Belt replacement, new lower control board (AMT only)
72 Belt replacement, lower control board version unknown
(AMT only)
73 Belt replacement, lower control board record bad (AMT
only)
74 Belt replacement, lower control board refurbished
console (AMT only)
75 Belt replacement, refurbished lower control board
(AMT only)
76 Belt replacement, console stride count is less than lower
control board (AMT only)
77 Belt replacement, console stride count is greater than
lower control board (AMT only)
78 Belt replacement warning (AMT only)