Precor P10 Heart Rate Monitor User Manual


 
54 Assembling and Maintaining TRM 800-Series Treadmills
2. Use the hex key to tighten the adjusting bolt toward
which the belt is shifting. Turn the bolt ¹₄ turn clockwise.
3. Recheck the belt position as described under Checking the
Alignment of the Running Belt.
If the belt ... Then ...
Continues to shift in the
original direction
Turn the same adjusting bolt an
additional ¹₄ turn clockwise.
Starts to shift in the
opposite direction
Turn the same adjusting bolt ¹₈ turn or
less counterclockwise.
Note: If the belt slips after you have adjusted it, tighten both
adjusting bolts evenly, ¹₄ turn at a time, until the slipping
stops. Do not overtighten the belt.
Storing the Chest Strap
If you purchased the optional heart rate chest strap, store it in
a place where it remains free of dust and dirt (for example, in
a closet or drawer). Be sure to protect the chest strap from
extremes in temperature. Do not store it in a place that may
be exposed to temperatures below 32° F (0° C).
To clean the chest strap, use a sponge or soft cloth dampened
in mild soap and water. Dry the surface thoroughly with a
clean towel.