Yamaha WR250FM Bicycle User Manual


 
3 - 21
INSP
ADJ
VALVE CLEARANCE INSPECTION AND ADJUSTMENT
Measure the valve clearance e using a
feeler gauge 1.
N
OTE:
Record the measured reading if the clear-
ance is incorrect.
6. Adjust:
Valve clearance
Adjustment steps:
Remove the camshaft (intake and exhaust).
Refer to CAMSHAFTS section in the
CHAPTER 4.
Remove the valve lifters 1 and the pads
2.
N
OTE:
Place a rag in the timing chain space to
prevent pads from falling into the crank-
case.
Identity each valve lifter and pad position
very carefully so that they can be rein-
stalled in their original place.
Select the proper pad using the pad select-
ing table.
Pad range
Pad Availability:
25 increments
No. 120
~
No. 240
1.20 mm
~
2.40 mm
Pads are available in
0.05 mm increments