6 - 7
– +
ELEC
IGNITION SYSTEM
AC MAGNETO INSPECTION
1. Inspect:
• Pickup coil resistance
Out of specification → Replace.
Tester (+) lead
→
Red lead
1
Tester (–) lead
→
White lead
2
Pickup coil
resistance
Tester selector
position
248 ~ 372
Ω
at
20 °C (68 °F)
Ω
×
100
RW
1
2
NEUTRAL SWITCH INSPECTION
1. Inspect:
• Neutral switch conduct
No continuity while in neutral → Replace.
Continuity while in gear → Replace.
Tester (+) lead
→
Sky blue lead
1
Tester (–) lead
→
Ground
2
Sb
1
Ground
2
Tester selector
position
NEUTRAL
Ω
×
1
IN GEAR
– +
Ω×1
1
2
L/WSb
EC628000
CDI UNIT INSPECTION
Check all electrical components. If no fault is
found, replace the CDI unit. Then check the
electrical components again.