Precor C954i Treadmill User Manual


 
page 4
COMMERCIAL PRODUCTS DIVISION
Diagram 1
Correct power
outlet for U.S.
Markets:
120-volt and
240-volt plugs.
120-volt grounding plug 240-volt grounding plug
GROUNDING INSTRUCTIONS
The C956i or C954i treadmill must be grounded. If it should malfunction or break down, ground-
ing provides a path of least resistance for electric current which reduces the risk of electrical
shock. The C956i or C954i treadmill is equipped with a power cord having an equipment-ground-
ing conductor and a grounding plug. The plug must be inserted into an appropriate outlet that is
properly installed and grounded in accordance with all local codes and ordinances Refer to
Diagram 1. If you do not follow these
Grounding Instructions
, you could void the Precor Limited
Warranty.
DANGER —
Improper connection of the equipment-grounding conductor can
result in a risk of electric shock. Check with a qualified electri-
cian or service person if you are in doubt as to whether the treadmill is properly grounded.
Do not modify the plug provided with the treadmill or use an adapter. If the plug doesn’t
fit the outlet, get a proper outlet installed by a qualified technician.
120V Units and 240V Units Designated for U.S. Markets
The C956i or C954i treadmill must be connected to a dedicated, grounded circuit. A 20 amp
dedicated circuit is recommended.
IMPORTANT SAFETY INSTRUCTIONS
SAVE THESE INSTRUCTIONS