ENG-55
Setup mode
Continue
Setting the record interval SAMPLE RATE
In primary measurement, the measurement data is recorded in the selected intervals
(seconds).
Stop the measurement and perform the resetting operation (page 26) before you *
change the record interval. Unless you perform the resetting operation, “DATA RESET”
appears on the screen, preventing change of the record interval.
You cannot set the record interval to off.*
1.
Press and hold the MENU button in the Clock mode or Sports
mode until “SETUP MENU” appears on the screen.
It switches to “CLOCK DATE” automatically.
Switch modes :
MENU
(press & hold)
2.
Switch to “SAMPLE RATE” pressing the MODE1 or MODE2
button, and then confirm it pressing the SSS button.
Switch screen :
MODE2
MODE1
(or)
Confirm :
SSS
3.
Select “T-10s (10 seconds)”, “T-5s (5 seconds)”, “T-3s (3
seconds)” or “T-2s (2 seconds)” pressing the MODE1 or
MODE2 buttons.
T-10s
↔
T-5s
↔
T-3s
↔
T-2s :
MODE2
MODE1
(or)
Pressing the
4.
MENU button confirms the change, and returns
to the Setup mode “SAMPLE RATE”.
Press the MENU button repeatedly to switch to another mode.
To the mode top/switch the mode :
MENU
The wristwatch stores up to 36000 points of data, and the maximum record time *
(maximum time up to the memory point utilization of 100%) depends on the intervals
of the seconds selected. The following time lengths can be used as a guideline.
T-10s (at intervals of 10 seconds) : up to 100 hours
T-5s (at intervals of 5 seconds) : up to 50 hours
T-3s (at intervals of 3 seconds) : up to 30 hours
T-2s (at intervals of 2 seconds) : up to 20 hours
The current memory point utilization can be viewed in the Data mode “File view” *
(page 39).
Current
record interval