Z 7 Tr e a d m i l l O w n e r ' s G u i d e
63
CARE AND MAINTENANCE
e failure code displayed will be “E-5 Sensor” when receiving the E5 Sen-
sor error, enter diagnostic mode and check the error log. Below is a list of
status display codes. When the drive is faulted, the Status LED blinks out
the default code. e code will blink the proper number of times, pause
with the LED off, and then repeat the code.
No Blink (Steady On) No Faults Running
Fast (Steady Blink) No Faults Ready
LED Off
AC Line Power
Insufficient
No or Low Voltage
1 Blink (E601)
100% Command Runaway Command
2 Blink (E602) Sensor Feedback Error Sensor Error
3 Blink (E603) Voltage Trip Error Motor Issue
4 Blink (E604) Output Over Current High Motor Current
5 Blink (E605)
Control Supply Under
Voltage
Inadequate Power Line
6 Blink (E606) Drive Over Temperature
MCB Over Tempera
-
ture
7 Blink (E607) AC Over Voltage Line Voltage Too High
8 Blink (E608) Output Short Circuit Short Circuit to Motor
E6 Level and Blink Codes
CARE AND MAINTENANCE
E6 LEVEL AND
BLINK CODES