CARE AND MAINTENANCE
e failure code displayed will be “E-5 Sensor” when receiving the E5 Sen-
sor error, enter diagnostic mode and check the error log. Below is a list of
status display codes. When the drive is faulted, the Status LED blinks out
the default code. e code will blink the proper number of times, pause
with the LED off, and then repeat the code.
  
No Blink (Steady On) No Faults Running
Fast (Steady Blink) No Faults Ready
LED Off
AC Line Power
Insufficient
No or Low Voltage
1 Blink (E601)
100% Command Runaway Command
2 Blink (E602) Sensor Feedback Error Sensor Error
3 Blink (E603) Voltage Trip Error Motor Issue
4 Blink (E604) Output Over Current High Motor Current
5 Blink (E605)
Control Supply Under
Voltage
Inadequate Power Line
6 Blink (E606) Drive Over Temperature
MCB Over Tempera
-
ture
7 Blink (E607) AC Over Voltage Line Voltage Too High
8 Blink (E608) Output Short Circuit Short Circuit to Motor
E6 Level and Blink Codes
CARE AND MAINTENANCE
E6 LEVEL AND
BLINK CODES