Battery sealing ring: Silicone
Operating temperature: -10 °C to +50 °C / 14 °F to 122 °F
Training computer materials: PMMA lens with hard coating in top surface, training computer body
ABS+GF metal parts stainless steel
Wrist strap and buckle materials: Polyurethane (TPU)/Silicone, stainless steel
Watch accuracy: Better than ± 0.5 seconds / day at 25 °C / 77 °F temperature.
Accuracy of heart rate monitor: ± 1% or 1 bpm, whichever larger. Definition applies to stable conditions.
Heart rate measuring range: 15-240
Current speed display range: 0-127 km/h or 0-75 mph (when measuring speed with s3+ stride sensor
or CS speed sensor)
0-400 km/h or 0-248.5 mph (when measuring speed with G5/G3 GPS
sensor)
Water resistance: 30 m (Suitable for bathing and swimming)
Training computer limit values
Maximum number of files:
99
Maximum time recorded to file: 99 h 59 min 59 s
Maximum time recorded to file with different sensor combinations:
Heart rate 99
Heart rate + stride sensor 26
Heart rate + GPS sensor 15
Heart rate + CS speed sensor 32
Heart rate + CS cadence sensor 61
Heart rate + stride sensor + GPS sensor 14
Heart rate + GPS sensor + CS speed sensor 15
Heart rate + GPS sensor + CS cadence sensor 14
Heart rate + CS speed sensor + CS cadence
sensor
26
Heart rate + GPS sensor + CS speed sensor +
CS cadence sensor
14
Stride sensor 32
Stride sensor + GPS sensor 15
GPS sensor 17
GPS sensor + CS speed sensor 17
GPS sensor + CS cadence sensor 15
GPS sensor + CS speed sensor + CS cadence
sensor
15
CS speed sensor 40
CS cadence sensor 99
CS speed sensor + CS cadence sensor 32
The training computer stores the data in five second intervals.
Maximum number of laps recorded in one training session: 99
Maximum number of automatic laps recorded in one training session: 99
Total distance: 99999.99 km / 99999.99 mi
Total duration: 9999 h 59 min 59 s
Total calories: 999 999 kcal
Total training files count: 65535
Heart rate sensor
Battery life of WearLink
®
transmitter W.I.N.D.:
Average 2000 hours of use
Battery type: CR2025
Battery sealing ring: O-ring 20.0 x 1.0, material silicone
Operating temperature: -10 °C to +40 °C / 14 °F to 104 °F
Connector material: Polyamide
Strap material: Polyurethane/Polyamide/Polyester/Elastane/Nylon
Water resistance: 30 m (Suitable for bathing and swimming).
The WearLink W.I.N.D. transmitter does not measure heart rate in water.
The Polar RCX3 training computer applies the following patented technologies, among others: