Bodyguard E350 Elliptical Home Gym User Manual


 
34
Quick Troubleshooting Check List
Table 5
For any further information regarding service isssues,
please contact your Authorized Bodyguard
®
Dealer.
PROBLEM
Computer will
not light on
when power
is turned ON.
Crank arms
are loose.
Upper frame
is loose.
No resistance
on pedals,
but computer
lights up.
Computer key(s)
not responding
to touch.
POSSIBLE CAUSE/SOLUTION
Check THE fuse – replace if necessary.
Check building electrical power line and fuse box – contact
qualified electrician.
The computer cable may be disconnected from the computer board
– inspect condition of this cable.
Check that power cord is functional – replace if necessary.
Remove the cover, tighten the bolts holding the crank arms (long &
short) with a hexagonal bolt 3/8.
Remove the cover and tighten the five screws holding the upper
frame to the base frame with the provided Allen key.
Speed sensor out of alignment – realign or replace if necessary.
Transformer or power supply board unit defective – replace
necessary parts.
With power OFF, verify that all wire connections are secure.
Keys may have been damaged from liquids penetrating behind seal
– replace computer display.
Excessive amount of cleaning solution used.
Use mild cleanser on damp cloth only when cleaning computer
console and unit.