![](https://pdfstore-manualsonline.prod.a.ki/pdfasset/5/0a/50a04dc1-fa29-4996-9b9c-eb154062e9f3/50a04dc1-fa29-4996-9b9c-eb154062e9f3-bg102.png)
4 - 111
MDS-D2/DH2 Series Instruction Manual
4.3 Setting the Initial Parameters for the Spindle Drive Unit
【#3043】 tapt23 Synchronous tapping 2nd step acceleration/deceleration time constant
(Gear: 10)
Set the time constant for synchronous tapping 2nd step linear acceleration/deceleration control
when gear 10 is selected.
---Setting range---
1 to 5000 (ms)
【#3044】 tapt24 Synchronous tapping 2nd step acceleration/deceleration time constant
(Gear: 11)
Set the time constant for synchronous tapping 2nd step linear acceleration/deceleration control
when gear 11 is selected.
---Setting range---
1 to 5000 (ms)
【#3045】 tapt31 Synchronous tapping 3rd step acceleration/deceleration time constant
(Gear: 00)
Set the time constant for synchronous tapping 3rd step linear acceleration/deceleration control when
gear 00 is selected.
The inclination of linear acceleration/deceleration control for 3rd step is determined by the ratio of
slimit1(#3001) to tapt31(#3045).
---Setting range---
1 to 5000 (ms)
【#3046】 tapt32 Synchronous tapping 3rd step acceleration/deceleration time constant
(Gear: 01)
Set the time constant for synchronous tapping 3rd step linear acceleration/deceleration control when
gear 01 is selected.
The inclination of linear acceleration/deceleration control for 3rd step is determined by the ratio of
slimit2(#3002) to tapt32(#3046).
---Setting range---
1 to 5000 (ms)
【#3047】 tapt33 Synchronous tapping 3rd step acceleration/deceleration time constant
(Gear: 10)
Set the time constant for synchronous tapping 3rd step linear acceleration/deceleration control when
gear 10 is selected.
The inclination of linear acceleration/deceleration control for 3rd step is determined by the ratio of
slimit3(#3003) to tapt33(#3047).
---Setting range---
1 to 5000 (ms)
【#3048】 tapt34 Synchronous tapping 3rd step acceleration/deceleration time constant
(Gear: 11)
Set the time constant for synchronous tapping 3rd step linear acceleration/deceleration control when
gear 11 is selected.
The inclination of linear acceleration/deceleration control for 3rd step is determined by the ratio of
slimit4(#3004) to tapt34(#3048).
---Setting range---
1 to 5000 (ms)