7-16
Cisco ONS 15454 Installation and Operations Guide
November 2001
Chapter 7 Card Provisioning
Provisioning Electrical Cards
Thresholds -
Line
CV Coding violations Numeric. Defaults:
• 1312 (15 minutes)
• 13120 (1 day)
ES Errored seconds Numeric. Defaults:
• 87 (15 minutes)
• 864 (1 day)
SES Severely errored seconds Numeric. Defaults:
• 1 (15 minutes)
• 4 (1 day)
FC Failure count Numeric. Defaults:
• 10 (15 minutes)
• 0 (1 day)
UAS Unavailable seconds Numeric. Defaults:
• 3 (15 minutes)
• 10 (1 day)
PPJC-Pdet Positive Pointer Justification
Count, STS Path Detected. See
the “Pointer Justification Count
Parameters” section on
page 8-12 for more information.
Numeric. Defaults (near end):
• 60 (15 minutes)
• 5760 (1 day)
NPJC-Pdet Negative Pointer Justification
Count, STS Path Detected. See
the “Pointer Justification Count
Parameters” section on
page 8-12 for more information.
Numeric. Defaults
• 0 (15 minutes)
• 0 (1 day)
PPJC-Pgen Positive Pointer Justification
Count, STS Path Generated. See
the “Pointer Justification Count
Parameters” section on
page 8-12 for more information.
Numeric. Defaults:
• 0 (15 minutes)
• 0 (1 day)
NPJC-Pgen Negative Pointer Justification
Count, STS Path Generated. See
the “Pointer Justification Count
Parameters” section on
page 8-12 for more information.
Numeric. Defaults:
• 0 (15 minutes)
• 0 (1 day)
Table 7-6 EC1-12 Card Parameters (continued)
Subtab Parameter Description Options