Other displays:
Dive time: 0 to 999 min, counting starts and stops
at 1.2 m [4 ft] depth.
Surface time: 0 to 99 h 59 min.
Dive counter: 0 to 99 for repetitive dives.
No-decompression time: 0 to 199 min (- - after 199).
Ascent time: 0 to 99 min (- - after 99).
Ceiling depths: 3.0 to 100 m [10 to 328 ft].
Air time: 0 to 99 min (- - after 99).
Displays only in Nitrox mode:
Oxygen%: 21 - 99.
Oxygen partial pressure display: 1.2 - 1.6 bar depending on the
limit setting.
Oxygen Limit Fraction: 1 - 110% with 10% resolution (bar
graph).
Logbook/Dive Pro le Memory:
Recording interval: 20 seconds (the recording interval can be set to
10s, 30s or 60s with the optional PC-interface unit and software),
records the maximum depth of each interval.
Memory capacity: approximately 36 hours of diving with 20
seconds recording interval.
Depth accuracy: 0.3 m [1 ft].
Operating Conditions
Normal altitude range: 0 to 3000 m [10000 ft] above sea level.
Operating temperature: 0°C to 40°C [32°F to 104°F].
Storage temperature: -20°C to +50°C [-4°F to +122°F].
It is recommended that the instrument be stored in a dry place at room
temperature.
NOTE! Do not leave the dive computer in direct sunlight!
Tissue Calculation Model
Suunto Deep Stop RGBM algorithm (developed by SUUNTO and
Bruce R. Wienke, BS, MS and PhD).
9 tissue compartments
Tissue compartment halftimes: 2.5, 5, 10, 20, 40, 80, 120, 240
and 480 minutes (on gassing). The off gassing halftimes are
slowed down.
Reduced gradient (variable) “M” values based on diving habit