Suunto VYTEC DS Watch User Manual


 
68
the blinking of the bar graph stops, when the PO
2
is below 0.5
bar
audible alarms are given and the actual PO
2
value blinks when
it exceeds the preset limit
in dive planning the maximum depth according to the O
2
% and
maximum PO
2
selected.
6.4. TECHNICAL SPECIFICATION
Dimensions and weight:
Vytec:
Diameter: 61mm [2.4in].
Thickness: 28mm [1.1in].
Weight: 68g [2.4 oz].
Transmitter:
Max. diameter: 40 mm [1.57 in].
Length: 80mm [3.15 in].
Weight: 118g [4.16 oz].
Rated working pressure: 300 bar [4000 psi], maximum
allowed pressure 360 bar [5000 psi].
Display resolution:1 bar [1 psi].
Depth Gauge:
Temperature compensated pressure sensor.
Salt water calibrated, in fresh water the readings are about 3%
smaller (calibrated complying with prEN 13319).
Maximum depth of operation: 80 m [262 ft] (complying with
prEN 13319).
Accuracy: ± 1% of full scale or better from 0 to 80 m [262 ft] at
20°C [68°F] (complying with prEN 13319).
Depth display range: 0 … 150 m [492 ft].
Resolution: 0.1 m from 0 to 100 m [1 ft from 0 to 328 ft].
Temperature display:
Resolution: 1°C [1.5°F].
Display range: -9 ... +50°C [-9 ... +122°F].
Accuracy: ± 2°C [± 3.6°F] within 20 minutes of
temperature change.
Calendar Clock:
Accuracy: ± 25 s/month (at 20°C [68°F]).
12/24 h display.